    60 TOP MOST CABLES – Electrical Engineering Objective Type Questions and Answers           



 1. The insulating material for a cable should have


 (a) low cost
 (b) high dielectric strength
 (c) high mechanical strength 
(d) all of the above 

Ans: d

2. Which of the following protects a cable against mechanical injury ?



 (a) Bedding
 (b) Sheath
 (c) Armouring
(d) None of the above
Ans: c


 3. Which of the following insulation is used in cables ? 


(a) Varnished cambric
 (b) Rubber
 (c) Paper
 (d) Any of the above

 Ans: d

4. Empire tape is



 (a) varnished cambric
 (b) vulcanised rubber
(c) impregnated paper
 (d) none of the above

 Ans: A

 5. The thickness of the layer of insulation on the conductor, in cables, depends upon



 (a) reactive power
 (b) power factor
(c) voltage
(d) current carrying capacity

 Ans: c

 6. The bedding on a cable consists of


 (a) hessian cloth
 (b) jute
 (c) any of the above
 (d) none of the above

 Ans: c

 7. The insulating material for cables should


 (a) be acid proof
 (b) be non-inflammable
 (c) be non-hygroscopic
 (d) have all above properties

 Ans: d

8. In a cable immediately above metallic sheath _____ is provided.


(a) earthing connection
 (b) bedding
 (c) armouring
(d) none of the above

 Ans: b

9. The current carrying capacity of cables in D.C. is more thanthat in A.C. mainly due to


 (a) absence of harmonics
(b) non-existence of any stability limit
(c) smaller dielectric loss (d) absence of ripples
 (e) none of the above

 Ans: c

 10. In case of three core flexible cable the colour of the neutral is


 (a) blue
(b) black
(c) brown
(d) none of the above

 Ans: a

 11 cables are used for 132 kV lines.


 (a) High tension
 (b) Super tension
 (c) Extra high tension
 (d) Extra super voltage
 Ans: d


12. Conduit pipes are normally used to protect _____ cables.


(a) unsheathed cables
(b) armoured
(c) PVC sheathed cables
 (d) all of the above

Ans: a

13. The minimum dielectric stress in a cable is at


 (a) armour
 (b) bedding
 (c) conductor surface
 (d) lead sheath

Ans: d

14. In single core cables armouring is not done to


 (a) avoid excessive sheath losses
(b) make it flexible
(c) either of the above
 (d) none of the above

 Ans: a

15. Dielectric strength of rubber is around


 (a) 5 kV/mm
 (b) 15 kV/mm
(c) 30 kV/mm
 (d) 200 kV/mm

 Ans: c

16. Low tension cables are generally used up to


 (a) 200 V
 (b) 500 V
(c) 700 V
(d) 1000 V

 Ans: d

 17. In a cable, the maximum stress under operating conditions is at


 (a) insulation layer
 (b) sheath
(c) armour
 (d) conductor surface

 Ans: d

18. High tension cables are generally used up to


 (a) 11kV
(b) 33kV
 (c) 66 kV
 (d) 132 kV
 Ans: a

19. The surge resistance of cable is


 (a) 5 ohms
 (b) 20 ohms
 (c) 50 ohms
(d) 100 ohms

Ans: c

 20. PVC stands for 


(a) polyvinyl chloride
(b) post varnish conductor
 (c) pressed and varnished cloth
 (d) positive voltage conductor
 (e) none of the above
 Ans: a

 In the cables, the location of fault is usually found out by comparing


 (a) the resistance of the conductor
 (b) the inductance of conductors
 (c) the capacitances of insulated conductors
 (d) all above parameters
 Ans: c

 22. In capacitance grading of cables we use a ______ dielectric. 


(a) composite
 (b) porous
(c) homogeneous
 (d) hygroscopic
 Ans: a

 23. Pressure cables are generally not used beyond


 (a) 11 kV
(b) 33 kV
 (c) 66 kV
 (d) 132 kV

Ans: c

 24. The material for armouring on cable is usually


 (a) steel tape
 (b) galvanised steel wire
(c) any of the above
 (d) none of the above

 Ans: c

 25. Cables, generally used beyond 66 kV are


 (a) oil filled
 (b) S.L. type
 (c) belted
 (d) armoured

 Ans: a

 26. The relative permittivity of rubber is


 (a) between 2 and 3
 (b) between 5 and 6
 (c) between 8 and 10
 (d) between 12 and 14

 Ans: a

 27. Solid type cables are considered unreliable beyond 66 kV because


 (a) insulation may melt due to higher temperature
 (b) skin effect dominates on the conductor
 (c) of corona loss between conductor and sheath material
 (d) there is a danger of breakdown of insulation due to the presence of voids

 Ans: d

28. If the length of a cable is doubled, its capacitance


 (a) becomes one-fourth
 (b) becomes one-half
(c) becomes double
 (d) remains unchanged

 Ans: c

 29. In cables the charging current


 (a) lags the voltage by 90°
 (b) leads the voltage by 90°
 (c) lags the voltage by 180°
(d) leads the voltage by 180°

 Ans: b

 30. A certain cable has an insulation of relative permittivity4. If the insulation is replaced by one of relative permittivity 2, the capacitance of the cable will become 



 (a) one half
 (6) double
 (c) four times
(d) none of the above

Ans: a

31. If a cable of homogeneous insulation has a maximum stress of 10 kV/mm, then the dielectric strength of insulation should be


 (a) 5 kV/mm
 (b) 10 kV/mm
 (a) 15 kV/mm
(d) 30 kV/mm

Ans: b

32. In the cables, sheaths are used to


 (a) prevent the moisture from entering the cable
 (b) provide enough strength
 (e) provide proper insulation
 (d) none of the above

 Ans: a

33. The intersheaths in the cables are used to


 (a) minimize the stress
 (b) avoid the requirement of good insulation
(c) provide proper stress distribution
(d) none of the above

 Ans: c

 34. The electrostatic stress in underground cables is


 (a) same at the conductor and the sheath
 (b) minimum at the conductor and maximum at the sheath
(c) maximum at the conductor and minimum at the sheath
 (d) zero at the conductor as well as on the sheath
 (e) none of the above

Ans: c

35. The breakdown of insulation of the cable can be avoided economically by the use of 


(a) inter-sheaths
(b) insulating materials with different dielectric constants
(c) both
 (d) none of the above
Ans: c

 36. The insulation of the cable decreases with 


(a) the increase in length of the insulation
(b) the decrease in the length of the insulation
(c) either (a) or (b)
(d) none of the above

 Ans: a

37. A cable carrying alternating current has 


(a) hysteresis losses only
(b) hysteresis and leakage losses only
 (c) hysteresis, leakage and copper losses only
 (d) hysteresis, leakage, copper and friction losses

 Ans: b


38. In a cable the voltage stress is maximum at


 (a) sheath
 (6) insulator
 (e) surface of the conductor
 (d) core of the conductor

Ans: d

 39. Capacitance grading of cable implies


 (a) use of dielectrics of different permeabilities
 (b) grading according to capacitance of cables per km length
 (c) cables using single dielectric in different concentrations
 (d) capacitance required to be introduced at different lengths to counter the effect of inductance
 (e) none of the above

 Ans: a

 40. Underground cables are laid at sufficient depth


(a) to minimise temperature stresses
 (b) to avoid being unearthed easily due to removal of soil
 (c) to minimise the effect of shocks and vibrations due to gassing vehicles, etc.
 (d) for all of the above reasons

 Ans: c

 41. The advantage of cables over overhead transmission lines is


(a) easy maintenance
 (b) low cost
(c) can be used in congested areas
 (d) can be used in high voltage circuits

Ans: c


 42. The thickness of metallic shielding on cables is usually


 (a) 0.04 mm
(b) 0.2 to 0.4 mm
 (e) 3 to 5 mm
 (d) 40 to
 60 mm

 Ans: a

 43. Cables for 220 kV lines are invariably


 (a) mica insulated
 (b) paper insulated
 (c) compressed oil or compressed gas insulated
 (d) rubber insulated
(e) none of the above

 Ans: c

 44. Is a cable is to be designed for use on 1000 kV, which insulation would you prefer ?


(a) Polyvinyle chloride
(b) Vulcanised rubber
 (c) Impregnated paper
 (d) Compressed SFe gas
 (e) none of the above

 Ans: d

 45. If a power cable and a communication cable are to run parallel the minimum distance between the two, to avoid interference, should be


 (a) 2 cm
(b) 10 cm
(c) 50 cm
 (d) 400 cm

Ans: c

46. Copper as conductor for cables is used as 


(a) annealed
 (b) hardened and tempered
(c) hard drawn
 (d) alloy with chromium

 Ans: a

47. The insulating material should have


 (a) low permittivity
(b) high resistivity
 (c) high dielectric strength
 (d) all of the above

 Ans: d

 48. The advantage of oil filled cables is


 (a) more perfect impregnation
(b) smaller overall size
 (c) no ionisation, oxidation and formation of voids
 (d) all of the above

 Ans: d

 49. The disadvantage with paper as insulating material is


 (a) it is hygroscopic
 (6) it has high capacitance
 (c) it is an organic material
(d) none of the above

 Ans: a

 50. The breakdown voltage of a cable depends on 


(a) presence of moisture
 (b) working temperature
 (c) time of application of the voltage
(d) all of the above

 Ans: d

 51. It is difficult to maintain oil filled cables.


 (a) Yes
 (b) No

 Ans: a

 51. In capacitance grading a homogeneous dielectric is used. 


(a) Yes
 (b) No

 Ans: b

 52. In congested areas where excavation is expensive and inconvenient ‘draw in system’ of laying of underground cables is often adopted.


 (a) Yes
 (b) No

 Ans: a

 53. Natural rubber is obtained from milky sap of tropical trees.


(a) Yes
 (b) No

 Ans: a

 54. Rubber is most commonly used insulation in cables.


 (a) Yes
 (b) No

 Ans: a

 59. Polyethylene has very poor dielectric and ageing properties.


 (a) Yes
(b) No

 Ans: b

 60. The metallic sheath may be made of lead or lead alloy or of aluminium. 


(a) Yes
 (b) No

 Ans: b

http://news.chivindo.com/487/ssc-je-upsc-ese-ies-gate-2018-iit-jam-2017-rajasthan-jen-dmrc-drdo-railway-je-metro-and-all-engineering-study-material-books-and-guidance.html

Comments

Popular posts from this blog

BT-BASIC commands used

8.10     Some of the most frequently used BT-BASIC commands used are: msi                               Changes default working directory. Mass storage is            Same as “msi” cat                               Catalogs (list)the node names in the specified directory.             get                               Brings the contents of a file into the system workspace.        ...

Perhitungan & Cara Merubah Kumparan Blender Dari 220 V Menjadi 12 V

          Seperti yang telah dijelaskan pada buku “menggulung motor listrik arus bolak-balik, servis peralatan listrik rumah tangga kelompok penggerak dan perbaikan peralatan listrik pertukangan”, bahwa motor penggerak yang digunakan pada perlatan listrik rumah tangga dan pertukangan seperti blender, mixer, bor tembak, gerinda dsb menggunakan jenis motor universal. Motor universal adalah jenis motor listrik yang dapat disuplai dengan sumber listrik arus bolak-balik (AC) dan arus searah (DC). Jadi peralatan-peralatan listrik rumah tangga dan pertukangan tersebut yang biasanya kita suplai dengan sumber listrik AC dari PLN atau Genset sebesar 220 V sebenarnya dapat juga kita suplai dengan sumber listrik DC yang tentunya tegangan juga harus sama yakni 220 V.           Yang menjadi permasalahan bagaimana kalau peralatan listrik rumah tangga atau pertukangan tersebut, sebagai contoh misalkan blender yang ingin digunakan atau dioper...

BT-BASIC command line

8.8       At the BT-BASIC command line type the command  msi  and the directory path, then press the “ENTER” key on the keyboard.  Example:                   msi ‘/hp3070/boards/aspect/main’ 8.9       At the BT-BASIC command line type the command  get ‘testplan’ and press the   ENTER” key on the keyboard.  You should now see the body of the testplan file displayed in the work space of the BT-BASIC window. 8.10     Some of the most frequently used BT-BASIC commands used are:

Autodesk SketchBook Pro 2021 Full Version

BAGAS31 – Sesuai dengan namanya, Autodesk SketchBook Pro 2021 Full Version ini merupakan software digital sketching atau drawing terbaik yang bisa kamu gunakan. Pada versi terbaru kali ini, ada beberapa penambahan fitur yang sangat efektif. Dengan fitur baru tersebut, diharapkan mampu meningkatkan proses sketching maupun drawing kamu. Autodesk SketchBook sendiri sudah bisa kamu dapatkan secara gratis melalui website resminya. Namun untuk kamu yang mau download versi Autodesk Sketchbook Pro, maka bisa langsung download melalui link yang sudah saya sediakan di bawah ini. Download Autodesk SketchBook Pro 2021 Full Version Screenshot: System Requirements: Windows 10 2.5 – 2.9 GHz of Intel or AMD CPU 4 GB of Memory 256 MB Graphics card with OpenGL 2.0 support We recommend that you use a pressure-sensitive tablet and pen for basic features Download: Autodesk SketchBook Pro 2021 Full Version [ FileUp ][ Uptobox ][ UsersDrive ] Jamu Only [ File...

Testhead

4.3         Testhead The testhead is that portion of the tester that supports the PIN, ASRU and Controller cards.   The testhead is divided into two BANKS and each BANK is divided into two MODULES, see figure 2 below.  Bank 1 contains modules 0 and 1, bank 2 contains modules 2 and 3.  The test fixtures are placed on the banks of the tester and locked down for board testing.  The testhead cards interface to the test fixture through the spring loaded pogo pin “nails” at the top edge on each of these card types. 4.4       Support Bay The support bay is a stand-alone cabinet that houses the power supplies for the Unit Under Test.  This bay also houses the test station power distribution unit and test station controller on earlier models. 4.5       Emergency Shutdown Switch The emergency shutdown switch is the large red button located at the lower left corne...

Kelebihan dan Kekurangan Saluran Listrik Jenis Saluran Udara dan Saluran Bawah Tanah

Berdasarkan pemasangannya,   saluran distribusi dibagi menjadi dua kategori, yaitu : saluran udara (overhead line) merupakan sistem penyaluran tenaga listrik melalui kawat penghantar yang ditompang pada tiang listrik. Sedangkan saluran bawah tanah (underground cable) merupakan sistem penyaluran tenaga listrik melalui kabel-kabel yang ditanamkan di dalam tanah. 1.    Saluran Bawah Tanah (Underground Lines) Saluran distribusi yang menyalurkan energi listrik melalui kabel yang ditanam didalam tanah. Kategori saluran distribusi seperti ini adalah yang favorite untuk pemasangan di dalam kota, karena berada didalam tanah, maka tidak mengganggu keindahan kota dan juga tidak mudah terjadi gangguan akibat kondisi cuaca atau kondisi alam. Namun juga memilik kekurangan, yaitu mahalnya biaya investasi dan sulitnya menentukan titik gangguan dan perbaikannya. Kedua cara penyaluran memiliki keuntungan dan kerugian masing-masing. Keuntungan yang dapat diperoleh dari suatu jaringan bawah...