Our Scope of Work : Batam indonesia

  Our Scope of Work : - Hazardous Waste / Normal Waste - Electrical Engineering Services - Mechanical Engineering Services - HVAC Engineering & Consulting - Pipe Works Services - Ship Repair - Carpentry Services - Service (AC) Air Cond & Compressore - Inspection Survey - Fumigation Services or (Non-Destructive Testing)  NDT services - Equipment Certification - Steel Works Services - Engineering Consulting - Marine Offshore Services - Annual Inspection for LSA & FFA( Fire Extinguisher,  Renew Certificate Liferaft) - Calibration Flowmeter in Batam Contact Sales doni.sudirman@chivindo.com Komplek Taman Pesona Indah Blok B11 Hp : 0823 8565 9499 

Total Electric Solution BATAM INDONESIA

  We cover every thing from residential, repair, maintenance & commercial projects. With a team of professionals, we offer a highly standardised regular electrical maintenance which is vital in keeping the latest standards for every electrical equipment to ensure maximum safety. We ensure that our electricians are regularly trained so as to provide you with the latest innovations and electrical services.. Similarly, we offer repair and maintenance services for industrial companies. We recognise that providing high-end electrical solutions in a professional, safe and suitable manner is crucial to the success of any business. We are distinctively qualified to meet the electrical needs of every customer. With our extensive years of experience, along with our specialty services, we have successfully completed a range of commercial projects for financial intuitions, professional offices, auto dealerships, residential complexes, retail centres as well as technology and manufacturing comp

Call Us for Electrical Maintenance Service BATAM INDONESIA

  Call Us for Electrical Maintenance Service If it relates to power distribution and electricity, we can fix it! Our insured experienced electricians take pride in what they do, and they perform quality work. Contact us to discuss your equipment and power systems maintenance and reliability needs! There are a number of compelling benefits to adding an electrical maintenance service agreement to your facility Preventive maintenance program. Protect Equipment and Extend Its Operational Life Just like getting regular oil changes on your car, staying proactive when it comes to preventive maintenance will save you money down the road. If you have special equipment like conveyor belts, compressors or pumps. This equipment already has manuals that tell you when general maintenance services are due. You can simply tie our service agreements in with those. But you can choose to use a different maintenance schedule interval. Control and Reduce Energy Cost Like with your car or other equipment, r

Wall Paneling

  The bulkhead panels are available as both the sandwich construction panel and the asymmetric shape panel. Modular construction with an insulation core of noncombustible material is between the facing of either laminate or sheet steel clad. We also have special solutions for wet areas such as galleries, laundry rooms, and shower areas. Contact Sales doni.sudirman@chivindo.com Komplek Taman Pesona Indah Blok B11 Hp : 0823 8565 9499 

bulkhead panels are available

  Contact Sales doni.sudirman@chivindo.com Komplek Taman Pesona Indah Blok B11 Hp : 0823 8565 9499  The   bulkhead panels   are available as both the sandwich construction panel and the asymmetric shape panel. Modular construction with an insulation core of noncombustible material is between the facing of either laminate or sheet steel clad. We also have special solutions for wet areas such as galleries, laundry rooms, and shower areas.

Jacketing Ducting in batam

  The purpose of insulation is to prevent the energy transfer, usualy divided into 2 kind of insulation. Hot and cold insulation. We able to design and   construct   insulation for building, marine, and piping. The material of insulation is refer to the client request according to the classification, we will offer option for more afrodable price to our customer with best material option. We can provide insulation with such material : Calcium Silicate Polyurethane Inject / Slab Rock Wool Glass Wool Elastromeric insulation Foamglass, etc To protect the insulation from any  damage , it should wraped/jacket/clad with covering material such as : Glass Cloth Aluminium Foil Aluminium sheet Galvanize sheet Stainless Steel Sheet Ulvashield, etc Contact Sales doni.sudirman@chivindo.com Komplek Taman Pesona Indah Blok B11 Hp : 0823 8565 9499 

Marine Accommodation & Interior Services

  Products and Services Cabin Modular System When any marine vessel is built, it is necessary to design residing space for passengers and crew member. This prefabricated modular system has complete lining and ceiling panels, unit toilets, door, furniture, lighting, air conditioning and ventilation system, fire alarms, windows and flooring. All these components are integrated and installed as one attached units, this cutting edge technology saves over 35% of construction costs. Wall Paneling The  bulkhead panels  are available as both the sandwich construction panel and the asymmetric shape panel. Modular construction with an insulation core of noncombustible material is between the facing of either laminate or sheet steel clad. We also have special solutions for wet areas such as galleries, laundry rooms, and shower areas. Ceilling Panel The  bulkhead panels  are available as both the sandwich construction panel and the asymmetric shape panel. Modular construction with an insulation co

PT CHIVINDO KREATIF FURNITUR BATAM INDONESIA

 Accommodation is paying full commitment to meet every requirements needed in marin industrial line. The Company is developed around key personnel who are vastly experienced in providing the service we offer. Personnel are selected through reputation in the industry, providing the company with a competent and professional services. Contact Sales doni.sudirman@chivindo.com Komplek Taman Pesona Indah Blok B11 Hp : 0823 8565 9499 

Register 1 controls the input of the RS-232 communications port

  Register 1 Register 1 controls the input of the RS-232 communications port as described in  Table 2 . Table 2    Settings for register 1  Field Description Octal Values BRKINT If BRKINT is set, break is mapped to SIGINTR. On Windows-based systems this field is forced by the system to be set. 000002 = set  000000 = not set ISTRIP If ISTRIP is set, it strips the 8th bit (8th bit is not read). This bit cannot be set on UnMux systems. 000000 = not set IGNCR If IGNCR is set, a received CR character is ignored (not read). 000200 = set  000000 = not set ICRNL If IGNCR is not set and ICRNL is set, a received CR character is translated into a NL character. 000400 = set  000000 = not set INLCR If INLCR is set, a received NL character is translated to a CR character. 000100 = set  000000 = not set IGNBRK If IGNBRK is set, a break condition detected on input is ignored, that is, not put on the input queue and therefore not read by any process. 000001 = set  000000 = not set IGNPAR If IGNPAR is s

BT-Basic Statements for RS-232 Communication

  BT-Basic provides several statements for using the RS-232 ports for communication. These statements enable the system to open and configure a port for RS-232 use. In order to transfer data using RS-232 protocol, an I/O port must be established and configured for RS-232 data transfer. This port is a physical connection to a serial device (such as a printer), from a port on the mux card. A pseudo-device file handles the actual transfer of data to and from the physical device. Thus, when you communicate via RS-232 you are actually accessing a pseudo-device file that the operating system maps to a physical device. Once an RS-232 file is created, the  assign to  statement allows the port (file) to be opened and accessed by the system for data transfer. Then the parameters associated with the RS-232 port are set with one or more  control  statements. The example program shown in  Example 1  demonstrates a data transfer using these statements. Example 1    Example of a data transfer assign

Calling User Functions from BT-Basic

  Calling User Functions from BT-Basic If you prefer to control remote instruments from the BT-Basic testplan, see  Example 7 . Although this method produces the same results as  Example 6 , the frequent interaction between BT-Basic and ATL make this a more complex way to do the test. Example 7  has an analog test that uses a high-frequency coaxial port ("FREQ_CNTR_HIGH" and "FREQ_CNTR_LOW") on the module to connect a frequency counter, FREQ_CNTR, to two nodes ("Node1" and "Node2") on the DUT and then make a measurement. The example works as follows: 1    BT-Basic starts the instrument server, calls a user function that sets the frequency counter to a known condition, and executes the analog functional test, "measure1". 2    ATL instructs the ASRU Card to make the connections between the frequency counter and the DUT and then passes control back to BT-Basic. 3    BT-Basic calls a function that makes the measurement, and stores the resul

DUT power supplies

  Power Products Table 47    DUT power supplies Product No. Model No. Description 44940A 6624A 1 4 outputs: 2 @ 0–7 V, 0–5 A or 0–20 V, 0–2 A and 2 @ 0–20 V, 0–2 A or 0–50 V, 0–0.8 A 44941A 6621A 2 outputs: 0–7 V, 0–10 A and 0–20 V, 0–4 A E4034A 6634B 1 output: 1–100 V, 0–1 A E3784A 6642A 1 output: 0–20 V, 0–10 A N1133A N5747A 1 output: 0–60 V, 0–10 A 1 The 6624A supply is also available in a faceless version (E3785A, 6624A Opt. J9). Table 48    PDU, MPU, Power Supplies Part Description E1135C PDU N1140-97000 Service Replacement PDU 200-240V 3-phase Delta (Option 3PD) N1140-97001 Service Replacement PDU 380-415V 3-phase (Option 3PN) N1140-97002 Service Replacement PDU 208-220V 3-phase Wye (Option 3PY) 2680-0278 screw, 10-32 for mounting PDU 2110-0051 10AF/250V fuse 2110-0012 0.5AF/250V fuse MPU N1140-8003 Module Power Unit (MPU) +5V / +24V Power Supplies E9900-63602 System Card clamshell with +5V / +24V power supplies