Skip to main content

TEST STATION READINES - AutoAdjust Program

11.0     TEST STATION READINES - AutoAdjust Program

11.1     The autoadjust program can be executed while logged in the user1 account.  This program will also run automatically whenever there is greater than a 5 degree change in the testhead air temperature.

11.2     To manually run the autoadjust program, type autoadjust at the BT-BASIC command
line and press the “ENTER” key on the keyboard. 

11.3     The program will begin executing and you will see the BT-BASIC window go blank.

11.4     The following message will appear in the BT-BASIC window:

AutoAdjust:    xxx of 472 tests completed.

11.5     The number in value xxx will increment from 1 to 472 as the test runs.  When the testing
is completed the system will restore the default BT-BASIC window, reference figure 7.

11.6     The test status will be displayed on the status line of the BT-BASIC window:
Completed = passed  or    AutoAdjust Failed = failed

11.7     If the autoadjust program fails, first manually re-run the “autoadjust” program.  If
autoadjust continues to fail then the test system self test should be run.


Note:   If autoadjust fails, the test system should not be used for production testing until the problem has been corrected.  Notify the test engineering department.