Table 16    Relays

Part
Description
03066-69903
SMT relay socket kit. Includes:
0490-1688
SMT relays x 6
03066-60400   
sockets x 6
0490-1814
pack of 12 0490-1804 relays

Table 17    Relays by card type

Card Type
Relay Function/Application
Relay Part Number
Relay Type1
System Card
MPU Enable
0490-2006
TH
Fixture Pull-down, Aux port (vacuum control)
0490-1828
SMT
Module Control Card
GP Relay
0490-1828
SMT
Misc. (ControlXT/XTP, 5V)
0490-1839 or 0490-2788
TH
ASRU Revision C Card
DUT Power Supply 1–4
0490-2006
TH
DUT Power Supply 5–6 (ASRU-C only)
0490-1727
TH
DUT sense, MOA, sub-MUX
0490-18042
TH
Trapped Charge Relay (Discharge K799)
0490-1828
SMT
Interconnect MUX, sub-MUX, probe, MOA, source, detector, functional. ports, interconnect MUX
0490-1688
SMT
ASRU Card, Rev D
DUT Power Supply 1-4
0490-2006
TH
DUT Power Supply 5-6 (ASRU-C only)
0490-1727
TH
Trapped Charge Relay (Discharge K799)
0490-1828
SMT
DUT sense, MOA, sub-MUX,Interconnect MUX, sub-MUX, probe, MOA, source, detector, functional ports, interconnect MUX
0490-1839
TH
Hybrid-144 Non-multiplexed Pin Card
Mux Relay (5 V)
0490-2067
TH
HybridPlus Card
MUX Relay (12 V)
0490-1688
SMT
MUX Relay (12 V)
0490-18042
TH
HybridPlus Card, Double-density, Programmable
MUX Relay (Programmable card only, 5 V)
0490-1839 or 0490-2788
TH
AccessPlus Card
GP Relay
0490-1828
SMT
MUX Relay
0490-1772
TH
Shield Relay
0490-1688
SMT
AnalogPlus Card
   E1172-66524
   E1121-66526

MUX Relay
MUX Relay

0490-1688
0490-18042

SMT
TH

1   TH = through-hole relay; SMT = surface-mount-technology relay

2   The 0490-1804 relay is available in a package of 12 using part no. 0490-1814



Comments

Popular posts from this blog

BT-BASIC commands used

8.10     Some of the most frequently used BT-BASIC commands used are: msi                               Changes default working directory. Mass storage is            Same as “msi” cat                               Catalogs (list)the node names in the specified directory.             get                               Brings the contents of a file into the system workspace.        ...

Perhitungan & Cara Merubah Kumparan Blender Dari 220 V Menjadi 12 V

          Seperti yang telah dijelaskan pada buku “menggulung motor listrik arus bolak-balik, servis peralatan listrik rumah tangga kelompok penggerak dan perbaikan peralatan listrik pertukangan”, bahwa motor penggerak yang digunakan pada perlatan listrik rumah tangga dan pertukangan seperti blender, mixer, bor tembak, gerinda dsb menggunakan jenis motor universal. Motor universal adalah jenis motor listrik yang dapat disuplai dengan sumber listrik arus bolak-balik (AC) dan arus searah (DC). Jadi peralatan-peralatan listrik rumah tangga dan pertukangan tersebut yang biasanya kita suplai dengan sumber listrik AC dari PLN atau Genset sebesar 220 V sebenarnya dapat juga kita suplai dengan sumber listrik DC yang tentunya tegangan juga harus sama yakni 220 V.           Yang menjadi permasalahan bagaimana kalau peralatan listrik rumah tangga atau pertukangan tersebut, sebagai contoh misalkan blender yang ingin digunakan atau dioper...

BT-BASIC command line

8.8       At the BT-BASIC command line type the command  msi  and the directory path, then press the “ENTER” key on the keyboard.  Example:                   msi ‘/hp3070/boards/aspect/main’ 8.9       At the BT-BASIC command line type the command  get ‘testplan’ and press the   ENTER” key on the keyboard.  You should now see the body of the testplan file displayed in the work space of the BT-BASIC window. 8.10     Some of the most frequently used BT-BASIC commands used are:

Autodesk SketchBook Pro 2021 Full Version

BAGAS31 – Sesuai dengan namanya, Autodesk SketchBook Pro 2021 Full Version ini merupakan software digital sketching atau drawing terbaik yang bisa kamu gunakan. Pada versi terbaru kali ini, ada beberapa penambahan fitur yang sangat efektif. Dengan fitur baru tersebut, diharapkan mampu meningkatkan proses sketching maupun drawing kamu. Autodesk SketchBook sendiri sudah bisa kamu dapatkan secara gratis melalui website resminya. Namun untuk kamu yang mau download versi Autodesk Sketchbook Pro, maka bisa langsung download melalui link yang sudah saya sediakan di bawah ini. Download Autodesk SketchBook Pro 2021 Full Version Screenshot: System Requirements: Windows 10 2.5 – 2.9 GHz of Intel or AMD CPU 4 GB of Memory 256 MB Graphics card with OpenGL 2.0 support We recommend that you use a pressure-sensitive tablet and pen for basic features Download: Autodesk SketchBook Pro 2021 Full Version [ FileUp ][ Uptobox ][ UsersDrive ] Jamu Only [ File...

Testhead

4.3         Testhead The testhead is that portion of the tester that supports the PIN, ASRU and Controller cards.   The testhead is divided into two BANKS and each BANK is divided into two MODULES, see figure 2 below.  Bank 1 contains modules 0 and 1, bank 2 contains modules 2 and 3.  The test fixtures are placed on the banks of the tester and locked down for board testing.  The testhead cards interface to the test fixture through the spring loaded pogo pin “nails” at the top edge on each of these card types. 4.4       Support Bay The support bay is a stand-alone cabinet that houses the power supplies for the Unit Under Test.  This bay also houses the test station power distribution unit and test station controller on earlier models. 4.5       Emergency Shutdown Switch The emergency shutdown switch is the large red button located at the lower left corne...

Kelebihan dan Kekurangan Saluran Listrik Jenis Saluran Udara dan Saluran Bawah Tanah

Berdasarkan pemasangannya,   saluran distribusi dibagi menjadi dua kategori, yaitu : saluran udara (overhead line) merupakan sistem penyaluran tenaga listrik melalui kawat penghantar yang ditompang pada tiang listrik. Sedangkan saluran bawah tanah (underground cable) merupakan sistem penyaluran tenaga listrik melalui kabel-kabel yang ditanamkan di dalam tanah. 1.    Saluran Bawah Tanah (Underground Lines) Saluran distribusi yang menyalurkan energi listrik melalui kabel yang ditanam didalam tanah. Kategori saluran distribusi seperti ini adalah yang favorite untuk pemasangan di dalam kota, karena berada didalam tanah, maka tidak mengganggu keindahan kota dan juga tidak mudah terjadi gangguan akibat kondisi cuaca atau kondisi alam. Namun juga memilik kekurangan, yaitu mahalnya biaya investasi dan sulitnya menentukan titik gangguan dan perbaikannya. Kedua cara penyaluran memiliki keuntungan dan kerugian masing-masing. Keuntungan yang dapat diperoleh dari suatu jaringan bawah...